Products

Product Categories

EFO Autotrip RCD Tester

The New EFO Autotrip RCD Tester is a powerful and comprehensive RCD Tester with unique time saving testing capabilities not found in other testers  the Market. The Autotrip RCD Tester can be used for testing at the socket outlet or also directly from the switchboard using the Accessory test leads.

SKU: AUTOTRIP Categories: ,
Description

EFO Autotrip RCD Tester

The New EFO Autotrip RCD Tester is a powerful and comprehensive RCD Tester with unique time saving testing capabilities not found in other testers  the Market. The Autotrip RCD Tester can be used for testing at the socket outlet or also directly from the switchboard using the Accessory test leads.

 

Faster RCD Operation Testing

To reduce RCD testing time the Autotrip has two automatic test sequence functions Quick Auto (2 Tests): 30mA x1 at 00 & 1800 and Full Auto (6 Tests): 30mA x½, x1, x5 at 00 & 180which allows the operator to set the test to start. Resetting the RCD at the distribution board during the test cycle then returning to the instrument to recall the trip time results. Additional design features include a hands free function. For rapid repeat RCD testing at distribution boards, Pass/Fail results, diagnostic ramp test (mA) and mains polarity. 

 

Product Features

Auto Test Sequence Functions.
Quick Auto RCD Testing ( 2 RCD Tests ).
Full Auto ( 6 RCD Tests ).
Hands Free operation.
Results Recall.
Trip Time ms.
Pass/Fail Results display.
Ramp Test.
Mains polarity.

 

Product Specifications

Supply Voltage Range 195 to 253V AC 50-60Hz.
Nominal Currents 10mA,30mA,100mA.
Test Current Accuracy x 1/2 +0% – 10%.
Accuracy x 1 +10% -0%.
Accuracy x 5 (30mA only) +/- 5%.
Test Current Accuracy Ramp +/- 5% of rated IN.
Trip Time Accuracy to 1.999s +/- (1% +1ms).
Fault / Touch Voltage 50V.
Over Voltage Protection 440V.
Measurement Range 5ms – 1999ms.
Operating Range Per EN61557 38ms – 1999ms.

 

Product Standards

 

Complies fully with the requirements of EN61010 and complies with the sections of EN61557.
Electrical Safety in Low Voltage Systems up to 1000V AC and 1500V DC as listed below.

EN 61010-2-030:2010 300V CATIII (Safety).
61326-2-2:2013 (EMC).
EN 61557-1:2007 (General performance).
61557-6:2007 (RCD performance).

 

Included Accessories

Instruction Manual.
Soft Carry Case.
Batteries.
Test lead 4mm banana plugs to 3 pin main plug.

 

Optional Accessories 

Part No: TL-30 Distribution board Lead Set as pictured below.

TL30 Test Leads